MYeBOX®. Energy Audits and Class A Power Quality

on .

Everyone is well aware of the importance of measuring electrical parameters correctly to help us make the right decisions regarding energy efficiency and its consequent short-term cost-effectiveness, but we often find that not only is it necessary to perform energy audits to quantify the energy consumed by our different installations, but power quality or transient events must also be detected and recorded at our installations.

Such power quality faults, although often referred to as hidden costs, lead to production downtime, loss of material, unproductive staff hours, etc., and in some cases may be much costlier for companies than poor energy management.

MYeBOX® is a new system enabling energy audits to be performed which comply with the ISO 50001 certification, quality analysis according to the EN 50160 Standard and now also class A certification under the IEC 61000-4-30 Standard.

Remote management

The MYeBOX system stands out from its competitors with its new connectivity features, allowing devices to be fully managed in a simple, intuitive way from any location via a mobile application or the MYeBOX Cloud platform. These tools allow the user to remotely access the device and verify connection, device configuration, parameterise desired logging intervals, enable and configure power quality or transient event detection, alarms and even start or stop data logging. The possibility to remotely view the parameters measured by the device on a mobile terminal allows the user to detect faulty installation and/or device configuration and correct any problems immediately. This leads to important savings in time and travel costs, other devices only detecting such faults after downloading the data and obliging the user to make several trips to the installation to retake measurements.

Versatility
MYeBOX®

One of MYeBOX's most outstanding features is that the device's wiring may be modified by firmware. What advantages does this have? Once the device has been installed, if the user detects that the parameters measured by the device are incorrect due to faulty wiring, data logging may be stopped, the device's wiring can be remotely modified and data logging resumed, thereby saving a trip without the need to retake measurements.

Single solution for simultaneous measurements

MYeBOX®By allowing remote configuration, the internal clocks of the devices can be synchronised via the mobile terminal or web platform, guaranteeing that all devices simultaneously logging at an installation have the same timestamp for all their logs. This is essential when determining the consequences or effects of a disturbance on the rest of the installation. If the devices being measured are not synchronised, it is impossible to draw cause/effect conclusions.

Remote management

One of the most recurrent needs of an energy audit is the need to carry out different measurements at different points in the same installation. This need usually requires long, costly journeys to the installations where the devices are measuring in order to stop data logging, move them to the new measuring point and restart logging. MYeBOX enables data logging to be stopped remotely and any company maintenance personnel (qualified and following safety guidelines) may then be asked to change the device's location. Once the device is in the new location, its correct wiring and configuration can be remotely checked, and data logging started again.

Multiple analysis

With a conventional analyser, the user is required to set a recording interval that applies to all variables. Although this may seem unimportant, it does penalise the user in that the recording interval for an energy audit to comply with EN50160 must be every 10 minutes. What happens if the user also needs to record some variables such as voltage and current every second? It simply cannot be done simultaneously. Such variables need to be recorded again and a one-second interval must be selected. MYeBOX is a precise, all-in-one device in that it allows the user to perform various types of installation analysis. How does it do so? It is the only analyser on the market that allows "per se" configuration of different recording intervals for different variables or variable sets. Logging of variables such as voltage and current per second may be configured and other variables can be recorded at 10-minute intervals.

Alarms

MYeBOX enables the configuration of certain alarms related to the value of some electrical magnitudes measured by the device. These alarms may be e-mailed to different users of that particular analyser, thereby actively controlling the installation.

MYeBOX®

MYeBOX may therefore be tailored to meet any requirements that help installers and maintenance managers make the right decisions at the right time, saving both indirect and direct costs in the most flexible, efficient way.

 

More information: MYeBOX®. Portable power analyzer

 

RECmaxCVM. Protect, reclose and measure. Avoid indirect costs to your installations by using reclosing systems

on .

Recent developments in electrical installations have given power supply continuity top priority among all users of the electrical network, especially in those industrial sectors where outages cause serious economic losses, either directly or indirectly. We are talking about plants whose industrial processes are vital, the telecommunications industry, the food and pharmaceutical industries, among others.

Power supply continuity is closely related to devices offering electric protection, another fundamental aspect of any electrical installation Protection devices are responsible for supply outages in our own installation, which may affect several lines depending on which protection device is involved.

Ideally, protection devices should trigger whenever there is a safety risk to those operating the installations or a risk of damaging machinery connected to the network. Having said this, protection devices not only trigger in the event of a real threat, but more often than not transient disturbances with no serious effect on the installation are responsible, and this type of scenario is precisely when protection and power supply continuity come into play.

As a result of the growing demand for solutions that aim to guarantee power supply continuity, devices have been developed to keep installations permanently working without risking personal safety or damage to machinery. Protection devices with self-reclosing systems are responsible for restoring power when there are no longer any risks of doing so. Thanks to such devices, the inconvenience, unnecessary costs and time wasted (in addition to the inherent output losses due to power supply shutdown) in manually switching circuit breakers back on are avoided, especially when they are sometimes located far away, are inaccessible or simply difficult to reach.

They have a wide range of applications since they are suitable for all isolated, mainly unsupervised installations, but where a good balance between safety and power supply continuity is of paramount importance.

What are the causes of untimely circuit breaker tripping?

Reasons for untimely tripping vary widely. From the presence of harmonic currents in the network to the variable behaviour of loads in the installation, including environmental factors such as lightning during a thunderstorm. As will be seen below, any tripping of protection devices in autonomous installations that are far away or difficult to reach leads to substantial losses for many industries.

Telecommunications industry

Telecommunications industry

Telecommunications centres for telephone, radio and television companies are often located on high ground like hills or mountainous areas to maximise the range they cover. When there are thunderstorms and lightning, any lightning that strikes areas adjacent to these centres could trip the earth leakage protection device. This event, though not causing any permanent system leakage, could render the telecommunications centre useless until a supervisor arrives to switch the circuit breaker back on. Bearing in mind the number of people affected by this type of situation, financial losses for telecommunications companies may reach tens of thousands of euros per minute.

The inconvenience and costs involved in bringing a technician to the area just to find out that the installation has not been seriously damaged must also be added to this cost.

Public lighting systems and traffic management
Public lighting systems and traffic management

In large cities, order largely depends on how traffic is managed. Correct synchronisation of traffic lights and signalling systems such as luminous panels are crucial for smooth traffic flow in large cities. Anything affecting elements that control traffic would lead to chaos, causing accidents or the busiest areas to come to a complete standstill.

Likewise, most public lighting systems operate independently and are difficult to monitor due to the presence of multiple lamp posts spread out everywhere. As in the case of traffic management, untimely tripping in this type of installation would affect a large number of people and constitute a serious road safety hazard.

Water and gas distribution systems

Water and gas distribution systems

Some water and gas supply phases take place in areas that are difficult to reach, thereby making it very complicated to restore supply. Furthermore, the typically slow response time of large companies to restore services could lead to outages lasting even longer.

Food sector companies
Food sector companies

Turning to other sectors such as food, we have an industry whose needs for continuous power supply are extremely demanding. Take the case of large supermarkets: this type of business cannot afford lengthy power cuts to lines where refrigerating chambers are connected, as this would adversely affect the state of the stored product and may even result in large quantities of goods being thrown away.

So what can we do to protect our installation without affecting power supply continuity?

Circutor's solution to the above-mentioned problems lies in the use of the RECmax CVM circuit breaker with self-reclosing earth leakage protection and inbuilt measurement.

Designed for power supply continuity

The RECmax CVM features an electric motor designed to operate the switch when reclosing. Reclosing options (sensitivity, delay, reclosure number, reclosure time intervals, reset times) are programmable and enable fully autonomous power recovery.

Protection continues to be a priority

The RECmax CVM includes an over-voltage and short-circuit protection device, and also offers earth leakage protection in the event of leakage in the installation. The device guarantees installation safety at all times.

What does CVM stand for?

The RECmax CVM features inbuilt measurement for over 250 electrical parameters, thereby enabling a much greater control over the installation's behaviour. The display shows the key variables in your installation, such as voltages, currents, powers, harmonic distortion, power factor... as well as important protection parameters: protection status, real-time leakage, total number of trips or number of trips per protection type. The device allows you to browse different menus using its keypad, which can also be used to configure various reclosing parameters: sensitivity, delay, reclosure number, reclosure time intervals, reset time.

RECmax CVM features inbuilt measurement for over 250 electrical parameters

Advantages of CIRCUTOR's RECmax CVM

Save time, space and money

The RECmax CVM's Plug&Play system minimises installation time to just a few minutes. Both the efficient MC measurement transformers and the WGC differential sensor are included in the kit, through which you simply need to feed the power cables, connect them to the device using the plug-in connection terminals, and the device is ready. The aforementioned wiring is all you need for the RECmax CVM to start operating, since it is self-powered through an internal connection to the circuit breaker.

Taking up just 7.5 modules of space for the 4-pole model and 5.5 modules for the 2-pole model, the RECmax CVM is a compact device suitable for installation in switchboards with limited available space.

The equivalent application with separate devices would require 3 more modules and cost 25% more.

Save time, space and money
Ultra-immunised

The ultra-immunised system, present in other products in Circutor's earth leakage protection range, offers the following advantages:

  • The earth leakage device triggers when reaching 85% of the threshold leakage value, which is when there is a serious risk to the installation and its users.
  • Immunity against high-frequency currents
  • Immunity against transient network variations
Installation control

Thanks to the RS-485 communications port, the RECmax CVM may be added to SCADA systems for remote device management, enabling in-depth analysis of device readings as well as remote configuration. The device features two configurable digital outputs, very useful for controlling alarms or other external systems.

By monitoring the unit, the status of the protection device may also be easily checked at all times, enabling remote intervention.

The backlight display, in keeping with other devices in our company range, allows protection device status to be instantly checked. In the event of tripping, the screen (normally green) changes to red in order to detect faults in the installation at a glance, displaying the value of the current that caused the system to trip.

Versatility

The RECmax CVM comes in 2-pole or 4-pole versions for all types of installations. Furthermore, the product range includes the possibility to choose from a 6A to 63A current range and a C or D trip curve.

RECmaxCVM

The above makes the RECmax CVM a very versatile product, an ideal device for:
  • SAVING: Maximises power supply continuity
  • SAFETY: Guarantees user safety and protects the installation's machinery.
  • MONITORING: Offers energy saving potential by monitoring, as well as detecting weak points in the installation that require preventive action.

RECmaxCVMMore information: RECmaxCVM

 


RECmaxCVM guarantess the electrical continuity from unwanted trippings

Saves energy with RECmaxCVM

RECmaxCVM Plug&Play system saves time and space

 

Energy Management Systems and consumption analysis

on .

The growing importance of electricity costs in businesses or at home has sparked a keen interest in understanding this consumption.

If you want to save on energy costs, you have to discover the reality hidden behind every power socket. You can explore alternatives which will stop consumption figures from boosting the final amount to quantities beyond your budget.

Basics of electrical installations for energy optimisation

Before attempting to take any steps to reduce electricity costs, the internal electrical grid must be understood. There are three essential categories to be considered when analysing problems:

  1. The total power contracted. It is reflected in the electricity bill and follows a standard type of consumption that meets consumer needs.
  2. The pattern of consumption based on industrial or domestic usage. In practice, this means the installed devices and the energy each unit needs to consume to operate correctly.
  3. Energy consumption rate per device. This stems from the previous category. For example, it specifies the time used by each power consumption device. A fridge will usually consume a continuous amount, whereas a dishwasher will probably consume a different amount from month to month. If you are able to identify these variables, then it is easy to manage power consumption.

It is very useful and revealing to break down contracted power consumption per installed electrical appliance and usage times. If you are unable to find a decent alternative to your consumption, you can always compare rates and offers from electricity companies. All include a discount on electricity consumption subject to individual contract conditions that also need to be evaluated

Keys to understand and calculate electricity consumption

Your electricity consumption may be conveniently tracked by using measuring devices such as energy consumption analysers. Any deviation in the usual rate caused by a device's malfunction is immediately detected. It is as simple as comparing the amounts consumed by the same device for previous periods.

The analysis of over 250 electrical parameters with references to energy, cost and equivalence in emissions shows whether current regulations on Energy Efficiency are being complied with or not. The documentation provided allows you to quickly configure the system, enabling you to safely and reliably track the consumption of your private network. You no longer have to mentally calculate consumption since rates are conveniently updated and even different sources of power are recognised. This is the case, for example, with auxiliary power units or UPS (Uninterruptible Power Supply).

A definitive state-of-the art solution providing complete control over the operation of an electrical network. Corrective actions have been clearly indicated for any detected malfunctioning.

Spain, together with Germany, has the highest electricity rates in the European Union. The actions you take to save energy lower its effect on your budget by saving important costs in the medium and long term. The solutions to any doubts arising from this section may be found on commercial networks offering these products.

Power analyzers

Consumption analyzers


Links of interest:


Can any capacitor bank with filters be used for power factor correction in networks affected by harmonics?

on .

The typical power factor correction solution for networks with harmonic distortion is usually based on standard devices, but the use of specific equipment is sometimes required in certain cases.

Capacitor banks with detuned filters

The specific characteristics of power factor correction in networks with high harmonic distortion levels, both in voltage and current, are now becoming more and more familiar to those who have to recommend the appropriate capacitor bank for each electrical installation.

Generally speaking, most companies that manufacture automatic capacitor banks include devices designed to be used in networks with a certain level of harmonic distortion in their catalogues. CIRCUTOR, in particular, offers a complete range of automatic capacitor banks, with both contactor and thyristor operation, as well as fixed compensation units, equipped with rejection filters (also known as detuned filters) with 189 Hz tuning frequency (in 50 Hz networks), equivalent to an overvoltage factor of p = 7 %. 

This 189 Hz tuning frequency is CIRCUTOR's default choice; it offers a suitable, effective solution for the vast majority of installations requiring a capacitor bank fitted with detuned filters, ideal when faced with order 5 harmonics (250 Hz in 50 Hz networks) or higher, which are usually produced by the most common sources of harmonic currents, i.e. three-phase loads equipped with a 6-pulse bridge rectifier at their input: variable speed drives or frequency variators, AC/DC rectifiers, induction furnaces, ...

In the less likely event of order 3 harmonics (150 Hz in 50 Hz networks) prevailing, the installation of detuned filters tuned to 134 Hz is included as an alternative (overvoltage factor of 134 Hz p = 14 %).

  • Does this standardised 189 Hz resonance frequency mean that the choice of capacitor banks should be made simply by choosing the necessary power from the standard models?
    The reply is simply: no.
  • Is therefore wrong to choose this 189 Hz frequency as standard?
    Once again, the reply is simply: no.

 

Where does the problem lie then?


Electrical network types

The answer to this question requires a brief look at the working principle of detuned filters. If we look at the impedance-frequency diagram of a reactor-condenser unit with p = 7 % (Fig. 1), we notice that it offers the lowest impedance at 189 Hz, and the impedance increases gradually on both of its sides, with the peculiarity that the impedance is capacitive for frequencies below 189 Hz, and inductive for higher frequencies.

"It is precisely this inductive behaviour in the presence of order 5 harmonic frequencies or higher that avoids resonance phenomena at any of these frequencies."

 

But the value of this impedance at the different harmonic frequencies, as well as the short-circuit impedance value at the capacitor bank's network connection point (Xcc at PCC), are also fundamental for the detuned filter to operate correctly.

Fig. 1 - Frequency response of a detuned filter with p = 7 % (189 Hz)
Fig. 1 - Frequency response of a detuned filter with p = 7 % (189 Hz)

In a network equipped with a detuned filter, a single-line diagram and an equivalent diagram as shown in Fig. 2, the standard behaviour is that the short-circuit impedance (Xcc) at the capacitor bank - network connection point (PCC) is significantly lower than the impedance at each step of the capacitor bank, so that each harmonic current step's absorption of the harmonic currents flowing through the network should be relatively low compared to the one flowing into the network, as this is the path with the lowest impedance.

But the situation may change in the event of networks where the Xcc value is high, i.e. in networks where the short-circuit power (Scc) at the PCC is low. These types of networks are also known as soft networks.

Fig. 2 - Single-line diagram and equivalent diagram of an installation fitted with a detuned filter

Fig. 2 - Single-line diagram and equivalent diagram of an installation fitted with a detuned filter

Installations that may be vulnerable to these problems are those with low short-circuit power in the High Voltage distribution lines at the low voltage network connection point; or those fed by a power transformer whose K-factor value (harmonic overload factor), by default, is unsuitable for the harmonic contents of the loads it is supplying, or there are long cable sections between the transformer output and the capacitor bank - network PCC, leading to high impedance in this section.

In these cases, the most common effect is an increase in harmonic currents absorbed by the capacitor bank steps. In some cases, such increase may be very serious, severely overloading the capacitors and reactors comprising each detuned filter, and, especially in the case of capacitors, increasing their deterioration, usually in the form of a decrease in capacity. This decrease in capacity even increases harmonic current absorption, because, as can be seen from the formula that determines resonance frequency (Fig. 1), a capacity decrease causes an increase in tuning frequency, meaning it is even closer to the harmonic frequencies in the network (remember that order 5 generally prevails), thereby reducing impedance at that frequency, which therefore increases consumption of currents of that order.

In other words, the detuned filter starts to react in a similar way to a tuned or absorption filter, but, as it is not designed to be used as such, its capacity is exceeded, causing it to deteriorate.

In addition to this effect, the fact that networks with low Scc values, in the event of high harmonic current circulation, usually display high harmonic distortion levels (THD(U)), is another factor leading to an increase in the harmonic current absorbed by capacitors.

In short, any solution that prevents an installed capacitor bank from affecting the network, and, in turn, avoids the capacitor bank itself being affected by the presence of harmonics in the network, may not always solve the problem, with the consequent technical and commercial implications this will undoubtedly entail.

Special solutions to be implemented

So what options do we have for these types of installations when considering power factor correction by means of a capacitor bank with detuned filters ?

The first consideration is obviously to determine whether the installation to be corrected is one that is exposed, i.e. a soft network type. Unfortunately there is no infallible or simple method of doing so, but there are a number of determining factors that help us find out to a reasonably high degree of accuracy. The main ones are as follows:

  • There is a noticeable decrease in voltage value between the no load and full load condition, and current harmonic distortion level (THD(I)) is above 15 % under full load status.
  • Voltage harmonic distortion level (THD(U)), at the point where the capacitor bank is to be connected, is above 3% under the installation's no load status.
  • Voltage harmonic distortion level (THD(U)), at the point where the capacitor bank is to be connected, is above 6% under the installation's normal load conditions.

If one or more of the above conditions are met, it is highly advisable to choose a capacitor bank fitted with detuned filters whose tuning differs from the standard 189 Hz (whenever, of course, the harmonics present in the network are of order 5 or above).

What tuning is recommended ?

For such cases, CIRCUTOR proposes a 170 Hz tuning value, equivalent to p = 8.7 %, which gives high capacitor bank protection levels when installed in networks of this type.

What do we achieve by this change in tuning?

Going back to the frequency response diagram for a rejection filter (Fig. 1), when the resonance frequency decreases, filter impedance on order 5 harmonics or above increases, so high consumption of these harmonic currents is significantly reduced. Furthermore, this change in tuning is also coupled with the use of capacitors whose nominal voltage is higher than those used in standard p = 7% filters, and reactors whose inductance value (mH) also exceeds the standard. As a result, we end up with a capacitor bank that is considerably more robust than its p = 7 % power counterpart.

Case study

A real case is described below, where the implementation of two rejection filter capacitor banks, with thyristor operation, and reactor-capacitor units tuned to 170 Hz, has enabled perfect network compensation, along with considerable improvement in power supply quality (voltage quality).

The installation is for a funicular railway in the city of Barcelona, whose simplified single-line diagram is shown in Fig. 3.

Fig. 3 - Simplified single-line diagram of the installation of a funicular railway in the city of Barcelona
Fig. 3 - Simplified single-line diagram of the installation of a funicular railway in the city of Barcelona

Fig. 4 - Installation of the funicular. The capacitor bank is shown on the left of the photo
Fig. 4 - Installation of the funicular. The capacitor bank is shown on the left of the photo

These types of installation show the same characteristics as those described above when it comes to identifying any possible problems should a capacitor bank with conventional detuned filters be installed, since they are usually located far from the high voltage substation that powers them, normally with a considerable distance between the MV/LV transformer and main load, in this case, the power transducer and operating motor, and, in particular, in the presence of a power transducer that causes a rather high current harmonic distortion level.

Situation prior to the installation of the capacitor bank

Fig. 5 shows the reactive and active inductive power evolution (1 s integration period) for one of the two transformers in the installation. The appropriate capacitor bank is a CIRCUTOR device with thyristor operation, 6 x 55 kvar / 500 V / 50 Hz / p = 8.7 %, disconnected.

Fig. 5 - Evolution for the Active Three-Phase Generated Power (red), Active Three-Phase Consumed Power (green), and Inductive Reactive Consumed Power (purple and blue)
Fig. 5 - Evolution for the Active Three-Phase Generated Power (red), Active Three-Phase Consumed Power (green), and Inductive Reactive Consumed Power (purple and blue)

Fig. 6 clearly indicates the effect of the current value supplied by the transformer on the mains voltage, another clear symptom of a soft network.

Fig. 6 - Evolution for Voltage between L1 and L2 phases (blue) and Current Intensity in L1 (green) at Point A
Fig. 6 - Evolution for Voltage between L1 and L2 phases (blue) and Current Intensity in L1 (green) at Point A

Fig.7 shows the evolution for voltage distortion levels THD(U), which are significantly higher at peak current consumption by the power transducer.

Fig. 7 - Voltage harmonic distortion evolution per phase at Point A
Fig. 7 - Voltage harmonic distortion evolution per phase at Point A

Fig. 8 - Voltage and current wave shapes at times of peak transducer consumption
Fig. 8 - Voltage and current wave shapes at times of peak transducer consumption

Present situation, after capacitor bank installation

Fig. 9 shows the reactive and active inductive power evolution (1 s integration period) for one of the two transformers in the installation. Capacitor bank now operational.

Fig. 9 - Evolution for the Active Three-Phase Generated Power (red), Active Three-Phase Consumed Power (green), and Inductive Reactive Consumed Power (purple and blue)
Fig. 9 - Evolution for the Active Three-Phase Generated Power (red), Active Three-Phase Consumed Power (green), and Inductive Reactive Consumed Power (purple and blue)

Fig. 10 shows how the decrease in current value supplied by the transformer significantly reduces network voltage variations, improving power quality.

Fig. 10 - Evolution for Voltage between L1 and L2 phases (blue) and Current Intensity in L1 (green) at Point A
Fig. 10 - Evolution for Voltage between L1 and L2 phases (blue) and Current Intensity in L1 (green) at Point A

Fig. 11 shows voltage distortion level THD(U) evolution when the power factor correction device is operating. Comparing these values with those in Fig. 7, a significant reduction in voltage harmonic distortion rates can be observed (around 40% for peak values). The connection of the capacitor bank has a double rate-reducing effect, by both absorbing a certain percentage of the harmonic current generated by the transducers on the part of the capacitors (in this case, no damage will be caused to the capacitors as they are specifically reinforced for such cases), and by reducing the current passing between the power transformer output and PCC, which significantly reduces the harmonic voltage drop in this cable, as well as reducing the transformer's own internal losses. In short, though high distortion levels are still present, network voltage quality improves to more acceptable values, leading to a noticeable improvement in the installation's power supply quality, thereby minimising the risk of the device malfunctioning.

Fig. 11 - Voltage harmonic distortion evolution per phase at Point A
Fig. 11 - Voltage harmonic distortion evolution per phase at Point A

Final conclusions

Having considered the foregoing, the best conclusion from those considered would be CIRCUTOR's standard, frequent recommendation to analyse, wherever possible, any installation whose power factor correction requires the use of a capacitor bank, to discard any doubts or fears we might have about possible effects of harmonic distortion in the network; an analysis that gives us the information required to make the right, safe choice of the most appropriate device to meet each particular case. With this in mind, please remember that CIRCUTOR has a full market range of network analysers, using state-of-the-art technology, which, together with effective data management software, enable any study to be carried out on the topics described in this article.

CIRCUTOR, your most reliable ally when requirements are related to power factor correction.

More information:

Solutions for Low Voltage Power Factor Correction

New CIRCUTOR corporate identity

on .

We’ve revamped our image

Here at Circutor we have launched our new communication strategy accompanied by a complete revamp of our corporate identity.

Future is Efficiency shows Circutor’s major contribution to the energy efficiency sector since it started out in 1973.

With this upgrade we seek to generate new points of connection with which to enhance the culture and values that our founders established right from the outset.

This will enable us to adapt to future global energy efficiency needs in order to continue developing innovative solutions with customers and suppliers which slowly but surely help to build a more efficient environment for all.

 

In-house presentation of the new corporate identity

 

On 28 March the new corporate identity was presented to the entire CIRCUTOR team at the Terrassa Cultural Centre.

It was a stirring and accessible event which introduced the company’s new corporate identity and reinforced the values which have always been part of CIRCUTOR:

  • We Write the Future: We create new solutions which inspire the electrical energy efficiency market.
  • We Build Together: We are our customers’ and suppliers’ partners. Working together is, and has been, the key to our success.
  • We Move Forward Responsibly: We look forward committed to the future. Responsible, caring for the environment we share.
  • People Here & There: We recognise and value people, everyone and all over the world. Open. Respectful and interested.
Presentation of the new corporate identity CIRCUTOR
Presentation of the new corporate identity at Hannover Messe

 

CIRCUTOR’s new corporate identity was publicly launched on 1 April coinciding with the start of the Hannover Messe 2019 trade show, the world’s leading industrial fair.

The new corporate image was on display at the CIRCUTOR booth to show its new brand image in public for the first time.

It is a new corporate identity which is not designed to change who we are but rather seeks to draw attention to what makes us unique.

Presentation of the new corporate identity CIRCUTOR

Spain ranks fifth for electric vehicle charging points

on .

Electric cars are an increasingly frequent sight in our cities. Spain is now the fifth most prolific country in Europe for zero-emission vehicles.

FD 5pais VE cargadorWhen sales of these vehicles began to take off, there were not so many charging points as there are now. Spain now has 3,856 public charging points for electric cars.

It is thanks to those charging points that Spain has the fifth largest infrastructure globally for these vehicles. The data were collected by Unieléctrica, based on figures from electromaps.com and the Spanish Institute of Statistics.

The United States occupies first place for infrastructure, followed by France in second, Germany in third and Holland in fourth.

New users of electric cars are recommended to find out all possible information from institutions and to ask in dealerships. Primary, they must be sure before buying whether they can charge their vehicle adequately in their location. The availability of charging points varies across the country. For example, in the region of Catalonia there are 939 charging points, and in Madrid there are 453.

Eco-friendly cars are becoming more popular across the globe. Numerous Governments across the world are supporting sustainable mobility. What once seemed impossible is now a reality; many companies are pursuing eco-friendly transport, and the number of private charging points is on the rise.

How do I charge my electric car?

All you need to do is connect your car to a charging point. You can usually find the cable in the boot of your electric vehicle. Once it is connected, the charging programme will begin automatically. The LED lights will indicate when charging begins and some cars have a charging current programme.

For the optimum charging of the battery of your electric car, you should be aware of the two different types of plugs. Around 30 models of zero-emission vehicles on the market have a type 2 “Mennekes” plug, which has been EU standard since 2013, designed by the alternative electrical charging company Mennekes.

For a quick charge, the Japanese electrical and automotive industry developed for 2019 the CHAdeMo connector. It is mostly used in Asia, but certain European electric car models are now using this kind of plug.

If you have an adaptor you can also charge your electric car battery at home, but only in an emergency, because domestic electricity infrastructure is not suitable for extended charging.

Recommendations for charging zero-emission vehicles

Tipo 2 ó Mennekes (IEC 62196-2)To fully charge your electric car battery, you need to ask two key questions: What kind of charging? What kind of plug?

Choose the charging mode (full or quick) according to your needs.
Get to know the models of electric cars and charging points in your city.


Link of interest: Move to zero-emission cars! They offer so many advantages.


 

Smart equipment and Systems
for electric vehicle charging

cat-rve
es en de fr pt

Harmonics: origin, effects and solutions

on .

Harmonic currents are one of the most important factors affecting network quality in installations, especially when it comes to wave shape. These currents cause distortions that distort the wave shape's ideal sinusoidal reference. This article will address harmonics from their origin to their consequences, as well as the tools available to electrical energy consumers to minimise their effects.

The presence of this type of parasitic currents in electrical installations (both domestic and industrial) has increased in recent years due to the growing implementation of so-called non-linear loads requiring the use of electronic converters to transform AC into DC and vice versa in order to work correctly. After the aforementioned transformation, the loads end up consuming current with a distorted wave shape.

Devices as common as computers require AC-DC conversion
Devices as common as computers require AC-DC conversion

Thanks to the mathematician Jean-Baptiste Fourier, this wave shape can be broken down into a sum of currents with multiple frequencies of the fundamental frequency (50 - 60 Hz).

We are therefore dealing with disturbances originating in the installations themselves, unlike other network quality factors such as amplitude, frequency or symmetry, which are usually caused by the power supplier.

In addition to the above-mentioned effects on the current's wave shape, current harmonics also have a distortion effect on the voltage wave, due to voltage drops that occur when these currents flow through the impedance of lines and transformers.

These distortions can be measured by network analysers and are mainly calculated as a percentage of distortion or harmonic distortion rate (THD). At an international level, there are standards that establish harmonic distortion limit values, which must be minimised to prevent them from affecting installations close to those being used by users (see IEC-61000-2-2; 2-4; 3-2; 3-4; 3-12; IEEE-519-2014).


After this conceptual introduction, let's now look at the most common non-linear loads:

  • Static transducers (rectifier devices, variable speed drives, soft starters, battery chargers...)
  • Single-phase electronic equipment such as computers, printers, programmable logic controllers, etc. Internally, they operate with direct current and have a filter capacitor and a rectifier at the input.
  • Lighting installations with discharge lamps.
  • Arc furnaces and welding equipment.
  • Transformers and reactors with iron core, and non-linear magnetisation.

most common non-linear loads

One of the most serious effects of current distortion caused by the above-mentioned loads is an increase in the network's effective current, leading to an unnecessary increase in consumption and problems related to cable and transformer sizing.


Its main consequences are:

Conductor overload

An increase in the effective current may cause currents flowing through the conductors to exceed their maximum acceptable limit, requiring an increased cross-section if the effect caused by the harmonic currents has not been accounted for. This problem may be particularly important for neutral conductors, since triplen harmonics (odd order, multiple of 3: 3, 9, 15), primarily caused by single-phase loads, cause harmonic currents to return through the neutral, all adding up together as one. It is essential to control overcurrent levels in the neutral, as excessive heating can cause serious degradation, even to the point of the neutral cutting off unless properly controlled. Neutral cut-off would lead to permanent overvoltage in the network, destroying equipment that is not suitably protected for such cases.

Derating of transformers

The presence of harmonics in the network increases hysteresis loss values and losses due to eddy currents in the transformers, increasing their operating temperature, which, in turn, reduces their useful life. This causes transformers affected by harmonic currents to suffer derating, that is, reduction in the power at which they can operate without causing overheating.

Triggering of protections

The effective current flowing through conductors may be seriously affected by an increase in current caused by harmonics in the installation, and may even exceed circuit-breaker temperature limits, thereby causing them to trigger. Although it is more unlikely, the presence of harmonics in circuit-breakers, due to their magnetic protection, may cause them to trigger, if the current's waveform crest factor exceeds the limit. High crest factors are often found in single-phase loads such as computers or discharge lighting. Harmonic currents have an indirect effect on RCCB triggering, since they flow through circuit breakers and do not directly cause them to trigger. On the other hand, it does mean that network behaviour upstream of the circuit-breaker has high impedance against harmonic currents, causing them to flow through parasitic capacitances or capacitance devices connected to earth (EMC filters), increasing the level of leakage found in the earth leakage device, thereby causing unwanted tripping.

Resonance and overload of capacitor banks

Capacitors are components that may display parallel resonance with the inductive behaviour of the transformer and cabling of the installation's power supply. This resonance greatly increases the unit's impedance to a given frequency that varies depending on the power of the capacitor bank or the power supply's impedance characteristics. Due to these characteristics of capacitor components, together with the presence of harmonics in the network, the installation may be affected by two detrimental phenomena:

  • Firstly, an increase in voltage distortion rate in any section of the installation affected by the resonance, which may affect other loads.
  • On the other hand, the capacitors themselves and other components in the capacitor bank, such as operating elements, may suffer damage as a result of their lower impedance against harmonic currents and high voltage distortion rate, leading to increased capacitor current consumption and possible capacitor burn-out.

Having dealt with the consequences of current harmonics, let's now look at the main problems regarding voltage harmonics:

Voltage distortion

Voltage distortion is a consequence of harmonic currents flowing through the impedances comprising the installation's different distribution and power supply components. Voltage distortion is particularly important, since high levels can cause devices in installations to malfunction, which is why there are compatibility level standards for this type of disturbances. The EN 50160 standard establishes conditions to be met by both the consumer and distributor at the coupling point (PCC), while the 61000-2-4 standard stipulates maximum distortion limits for correct operation of different types of loads. Different types of environment are also specified in this standard. By way of example, the voltage distortion limit for class 1, which includes sensitive loads such as automated systems, computers, etc., is 5%. This means that for higher distortion rates, such loads may be affected and operate incorrectly.

Effect on induction motors

Induction motors will suffer higher losses from an increase in parasitic currents. Furthermore, depending on the rotation sequences induced by the magnetic fields caused by voltage harmonics, the motor may suffer accelerations (positive sequence), braking (negative sequence), or both simultaneously, causing vibrations and eccentricities leading to mechanical wear of components. Derating of motors compared to voltage distortion rate is described in EN 60034-12 and NEMA MG1. In short, the factors identified lead to a loss of torque in the motor and reduced performance.

Zero-crossing disturbances

Many electronic devices have controllers that trigger load operation when voltage crosses zero. This is used to minimise switching current peaks in many inductive loads, thereby reducing the negative effects on electromagnetic compatibility levels. In the event of voltage distortion, such devices may operate incorrectly, causing them to break down, enter a loop, reset, etc.

Zero-crossing disturbances

Once the origins and effects of harmonics have been analysed, it should be pointed out that the purpose for eliminating them from electrical installations is not merely economic, but also helps to guarantee high-quality electric power supply. Unlike what happens with the power factor, nowadays there are no penalties for problems related to the presence of harmonics in electrical energy consumer networks.

In terms of cost saving, although we have already mentioned that harmonics increase the effective current and thus lead to increased energy consumption, it is not advisable to use harmonic filtering solutions in order to reduce additional losses, since the equipment needed to do so would hardly save any costs in consumption.


So why should we reduce the presence of harmonics in our installations?

The answer to this question lies in the advantages of having high-quality electrical energy flowing through our power supply:

Avoiding needless tripping of protections and ensuring devices run smoothly will help to maintain service continuity, so important in any industrial activity.

Keeping distortion rates to a minimum will lead to substantial saving in equipment maintenance costs, ensure that devices always run smoothly under optimum conditions, and avoid premature breakdown affecting both service continuity and high repair or replacement costs.

Besides these considerations, safety in electrical installations must be considered a top priority, especially considering the presence of personnel working with machinery and the need to avoid serious incidents such as fires. With this in mind, correctly dimensioning cabling and devices to suit operating conditions is crucial when it comes to reducing insulation faults and overheating of components.

CIRCUTOR's proposal: Active AFQm filters

Circutor's latest innovation in harmonic filtering comes with the release of the new AFQm active filters. The new AFQ series has been revamped and now offers extra versatility thanks to a more compact, lighter, efficient modular design and the proven top-quality track record of its predecessor, the AFQevo.

The working principle of the AFQm filter is the injection of a counter-phase set of currents into the harmonic currents flowing through the network. The device measures the distortion rate that occurs and then counterbalances it to obtain the best possible setting for an ideal sine wave, as illustrated in the figure below:

Working principle of an active filter
Working principle of an active filter

In this way, high-precision filtering is achieved, helping to maintain a top-quality power supply, which, in turn, leads to more efficiency and better overall functioning of the installation's components, as explained earlier in this article.

Due to the high level of harmonics in today's electrical installations, AFQm active filters can be used in a wide range of applications, especially in industries where an optimum wave shape is essential.high-precision filtering


Characteristics of the active AFQm filter

Multifunctional
Multifunctional

The AFQm eliminates harmonics and guarantees your installation's power supply quality.

Active multifunction filter, with primary selection of the following items:

  • Harmonic current filtering
  • Phase balancing
  • Reactive power compensation

 

Practical
Practical

Quick installation and easy step start-up.

The device just needs to be connected to the filter's network and measurement transformers, configured using its touch screen and then started up. The device itself will check that start-up is safely carried out thanks to an internal self-diagnosis system.

Interactive
Interactive

Its colour display allows the device to be configured and its installation status shown in real time.

  • Easy device configuration with clear, guided steps. The harmonics to be filtered can be selected individually for optimum device operation.
  • Troubleshooting connection problems: Faced with a common problem such as incorrect measurement transformer connection, you only need to enter the configuration menu to correct it in a few clicks.
  • Real-time display: Filter status, main electrical parameter readouts, phasor diagrams, wave shapes and harmonic spectrum are also displayed on the touch screen in real time. Information is displayed to the user in a very visual way by graphs and diagrams, so the behaviour of the installation and device may be instantly checked . The device also displays information for the 5 seconds prior to alarm activation to totally control installation status.

Troubleshooting connection problemsReal-time display

Modular

Find the combination that best suits your filtering needs

Modular

The compact AFQm range consists of 3 wall-mount models: 30A, 60A and 100A. Compared to the previous model, the new active filters are now more compact, lighter, quieter, and, since several arrays are possible, a lot more versatile too. For installations with higher filtering capacity requirements, 100A models may be installed in a cabinet-type array, obtaining cabinets reaching 400A. In such configurations, there will only be one master module, responsible for managing the whole filtering system. In this way, far fewer measurement transformers and much less electrical wiring are required, since only 3 measurement transformers need to be connected to the master and the CAN bus wiring to the slave modules. In the event of an even higher filtering demand, the master-slave function can be expanded to 100 parallel connected units.

ModularModular

Communicable

Manage the device wherever you are via PC or mobile devices

The AFQm includes Ethernet TCP/IP and Modbus TCP communications for on-line web site monitoring , and format may be directly downloaded (without the need for software). Furthermore,the device may be fully configured with all on-screen configuration features, including filter status that may be monitored in real time and remotely.

As an example, the device may be started up and monitored remotely, on-site personnel only being required to physically install the filter. As a result, the cost of sending technical personnel to the installation is spared, allocating such resources only when strictly necessary.

Traceable
Traceable

All readings are stored in the device's memory so no data is lost

The filter stores readings with a one-minute interval and has a 7-year data recording capacity thanks to its 2 Gb internal memory. These data records may be accessed via communications for in-depth analysis of the installation's behaviour.

Safe

Thanks to the device's inbuilt, low-maintenance systems, the product's service needs are kept to a minimum

The AFQm has a variety of systems to guarantee filter safety during operation:

  • Protection system to prevent start-up if there is a problem
  • Anti-resonance system: the device is designed to bypass specific frequencies where resonance is detected
  • Smart thermal management system: fan speed and power regulation under high temperature conditions
  • Safe mode activation in case of fault detection
  • The device performs self-diagnostic tasks for the code and hardware executing it

Safe mode activation

Consult all information regarding Circutor's new AFQm active filters:

CVM-A1500A. Supply quality management in industry

on .

Continuity in supply of raw materials and the constant flow of resources to production processes have been crucial in preventing financial losses due to production stoppages. As is well known, in both industry and business, time is money.

Production stoppages bring with them financial losses and in most cases they are down to lack of planning, whether due to a logistics issue, lack of preventive maintenance or many other similar problems. There are numerous obvious and visible causes and also others which are harder to identify.

Poor power supply quality is one of them; you cannot see it and its impact may be as serious as any lack of raw material for your production processes. The technology of the machinery involved in these processes is increasingly sophisticated and delicate while the quality of the voltage waveform is taken for granted in most designs.

Many maintenance managers are called in when a machine stops working properly or just comes to a halt for no apparent reason. From then on the experience of the manager and their team comes into play to spot the fault or to restart the system. It is likely that the system will resume operating without any further incidents, meaning the real problem remains unknown and may crop up again at any time with no apparent cause.

There’s no doubt you are getting swells, dips or interruptions in the power supply, and it may be that the electronic systems’ circuit breakers bring the machinery to a halt to prevent damage which can turn out to be very expensive.

Protecting your system against these kinds of problems may also call for significant investment, yet everything depends on how often you have these problems and the impact they have on your operations.

An initial and much more affordable measure is installing a device which can detect and log those problems. With the information from this device you will be able to address the problem with greater chances of a successful outcome.

FD CVM-A1500 factory

Analysing the installation using network analysers

As we have seen, it is crucial to have real information about the status of the electricity network in order to be able to detect whether a production stoppage is due to the quality of the power supply. For this purpose, there are network analysers which can help maintenance managers to understand what is going on at any given time in order to make the best decision, either to avoid production stoppages or to mitigate their impact.

To try to make performing this task as easy as possible, Circutor has designed its CVM-A1500A power quality analyser. It will quickly report any network quality incidents which may occur in a facility so that action can be taken straightaway.

This model is certified under the IEC 61000-4-30 standard and detects faults in power supply quality in the waveform from the half cycle (from 10 ms in 50 Hz networks and 8.3 ms in 60 Hz networks), providing complete information to maintenance managers about the problem. By installing several units at key points in the installation you can get a clear idea of when, where and how a power supply quality problem has impacted it.

The CVM-A1500’s user interface and integrated Web server provide easy, convenient and intuitive access to information about any power quality problems identified.

You don’t have to be an expert to interpret its data

The downside when it comes to analysing network quality has always been the interpretation of data by a specialist engineer. Some installations have quality equipment installed but it is not used because users have difficulty in interpreting its data.

Quality analysers are normally “black boxes” which do not provide information if they are not connected via data interpretation software.

So in addition to needing computer skills to download their data you also have to know about their computer program for interpreting these data. If you additionally combine equipment from several manufacturers, then the task is even trickier.

That’s why Circutor has developed a model featuring browsing by colour screens to provide relevant information for decision making.

ITIC curve

The CVM-A1500A analyser shows the ITIC (also CBEMA and SEMIF 47) curve on the screen. With just three clicks on the equipment, any maintenance manager can display the ITIC curve.

This curve shows red triangles each time an event occurs, quickly displaying how many quality events there have been and how damaging they have been for the installation. This means you can swiftly see what kind of problem you are faced with.

If the triangles are in the green zone, this means that there have been events (power surges or voltage drops) which have not harmed the electronic equipment in your facility. However, if the triangles are in the red zone, this will mean a swell which has most likely damaged your electronic equipment. The closer the triangles are to the top left, the more damaging they will be due to their high value and duration. By contrast, if the triangles are in the yellow zone this means that there have been voltage drops. These voltage drops may impact electronic systems leading to rebooting or stoppage due to low voltage.

Just by glancing at this screen, any maintenance manager will know why there might have been a malfunction. Furthermore, if it is repeated regularly, they will have more information to install a system which mitigates the event’s impact thus avoiding production stoppages and hence financial losses.

ITIC Curve
ITIC Curve

Installation events

In addition to the curves we have discussed above, the equipment has an event counter which shows you how many there have been in each phase so you will know whether the problem always comes from the same phase or if it is repeated regularly. To get a closer look, you can use the analyser’s screen to review each event individually and view it in detail. With several clicks on its screen you enter the event and see in which phase it took place, what its voltage percentage is, what voltage there was before the event (this helps you see whether it was a fast event due to switching or a slow one due to overloading), how long it lasted (from the half cycle) and on what date and at what time it occurred. Plus you can always enter the event to see its associated waveform, showing the voltage sinusoid to see exactly when it happened.

Quality event
Quality event

Transient associated with a quality event
Transient associated with a quality event

Other parameters to be checked to ensure the proper operation of an installation

We have seen how voltage events may bring about production stoppage which leads to financial loss. Furthermore, power supply quality analysers can help us avoid future problems in the installation by checking other relevant parameters.

Harmonics

Harmonic decompositionThese devices show harmonic decomposition up to 63, and you can see what level of harmonic load you have in the installation. Harmonics can impact the installation’s performance and also trip a circuit breaker or lead to overheating or malfunction of electronic loads.

Unbalances

Quite often installations have uneven currents in the various phases due to poor load distribution or a subsequent line extension. This effect may lead to current flowing through the neutral wire. In these cases it is essential to measure the current flowing through the neutral conductor to avoid possible insulation failures which can cause breakage that leads to swells, thus damaging components of the installation. Furthermore, if the installation has its own distribution transformer, this may overheat resulting in premature ageing and changing its useful life. To avoid these hazards, the CVM-A1500 network analyser measures neutral current along with any unbalance in voltages and currents and reports any situation that may entail a risk for the installation both onscreen and by email.

Data display on a PC

The CVM-A1500A analyser has a web server with built-in memory. Any user can access the logged data on a web browser (Internet Explorer, Firefox, Google Chrome, etc.) to monitor all parameters in real time, produce graphs and tables, view quality events and waveforms and extract data easily in Excel without having to be an expert in power supply quality software. Plus the equipment can be integrated with our PowerStudio Energy Management Software (EMS) and can be integrated into a complete network with equipment for usage management to provide an overview of the installation’s entire status.

Access by web browser or PowerStudio software
Access by web browser or PowerStudio software

Network quality at a glance

As we have seen, with the CVM-A1500A power supply quality analyser any user can have complete control of the parameters which may bring about a malfunction in any installation and also check where an electrical fault comes from, whether it be internal or external. By exporting data, maintenance managers can negotiate with the electric utility in case of a stoppage due to poor power supply quality or may even demand guarantees for all machines with anomalous operation as they can check whether the failure is the result of an external cause or due to malfunction of the machine itself.

The quality of your installation under supervision


More information: CVM-A1500

REC4. Comfort at home, continuity in infrastructures

on .

Earth leakage protection is one of the most important systems in electrical installation safety.

Circuit breakers must always trip whenever a dangerous leakage level for humans is reached or they can cause economic losses to electrical installations. That said, these elements do not only trip on occasions caused by leakage in the installation, but due to external factors too, such as thunderstorms which frequently occur.

Self-reclosing RCCB devices are circuit-breakers with a built-in motor, whose function is to reclose if there is no permanent leakage in the installation.

This article presents a new design in Circutor's REC series, the REC4, as well as highlighting the benefits of installing such a device.

The device

FD REC4 3-en

The new REC4 is a development of its predecessor, REC3, in terms of size, while maintaining all its features. The device now takes up only a 3-module space, which means that it can be easily installed in new or existing electrical panels.

It is also the ideal solution for panels with limited space, replacing the standard earth leakage protection (2 modules) and the thermal magnetic circuit breaker (2 modules) with the REC4 (3 modules) and a unipolar thermal magnetic circuit breaker (1 module), also referred to as DPN. Automatic reclosing is therefore incorporated by taking up the same space, avoiding the need to enlarge the electrical panel.

REC4

The REC4 also includes the possibility to cancel the reclosing system by selecting manual or automatic mode, and may be sealed up to prevent tampering during maintenance work or once in operation.

Once installed, it has LED indicators to quickly, visually check its status (ON/triggered/reclosing) at all times.

To ensure full personal safety, the device is equipped with protective insulation, which deactivates the automatic reclosing system in the event of direct contact during handling, thus avoiding any injuries during start-up or maintenance work.

Its installation is really simple, since its compact size allows it to be fitted as a current circuit breaker, and the user does not need to make any type of connection between the circuit breaker and the motor, as it is completely built into its housing.

Maximum continuity, minimum space

FD REC4 espacio-en
 
The REC4 is a device designed for all those installations where service continuity is essential. As you will notice, there are many possible uses for Circutor's self-reclosing RCCB device, which is suitable for any type of electrical installation thanks to its compact dimensions.
Comfort at home

The REC4's functions make it particularly well-designed for domestic use, where most loads are single-phase. More and more devices operate autonomously and are controlled remotely. This is why RCCB tripping may cause several household problems.

FD REC4 vivienda1When we are away from home on holiday and the circuit breaker trips, the cables connecting electrical appliances such as fridges to the mains may become damaged, causing the contents of the fridge to get spoilt in a matter of hours. This problem causes economic losses in having to get rid of food and make us waste time cleaning it and switching it on again.

FD REC4 vivienda2Another example of the way the REC4 self-reclosing RCCB can be used is to prevent tripping from disconnecting the home's burglar alarm, leaving the premises unprotected against vandalism and theft. Installations such as air conditioning, lighting, garden irrigation or pool maintenance are also remotely controlled nowadays by mobile devices. The device will help us to keep them working at all times, avoiding surprises on arriving home or at our second residence, the latter being possibly the most important case for our self-reclosing RCCB device.

FD REC4 infra1

However, the advantages are not just restricted to guaranteeing constant functioning of household appliances when we are away from home. There will be numerous occasions on which we will appreciate the REC4 self-reclosing device, e.g. when the lights suddenly go out at home, sparing us the discomfort of moving in the dark to the mains panel to flip the switch.

Continuity in infrastructures

The main reason to equip infrastructures with the REC4 circuit breaker is to maximise single-phase load service continuity. The device will reclose almost instantly as long as there is no permanent leakage, avoiding shutdowns in different systems that lead to substantial economic losses which must be avoided at all costs.

FD REC4 infra2Wherever equipment is operating autonomously from a remote location, Circutor's self-reclosing RCCB will safely reclose in the event of protections tripping.

In the event of transient leakage tripping, the system will ensure that the installation continues to operate normally. On the other hand, if permanent leakage is really occurring, the system will try to reclose up to three times and if it the leakage persists, reclosing will not be completed, leaving the circuit open for a specialist to inspect it.

FD REC4 infra3For example, in the telecommunications industry it is very common to have different antennas spread over the country, with some of them located far away or inaccessible. A downtime in this type of infrastructure could lead to losses of around €30,000/min for the company, in addition to the cost and inconvenience of displacing personnel to the site to simply flip the switch.

Other examples along these lines would be public lighting installations, guaranteeing that the lighting system works in the city or on the roads, or the reclosing of low-cost petrol station facilities that do not have personnel on site to manually carry out reclosing. Instead of moving to locations to restore normal operation, the REC4 would restore the installation's proper functioning.

FD REC4 infra4As regards the services sector, having the self-reclosing RCCB would be an important asset in systems like lighting, air-conditioning, surveillance camera networks or uninterruptible power supplies (UPS) to keep them working at all times, both in small establishments and large stores or shopping centres.


Discover how it functions and how to install it

 

More information: Self-reclosing RCCB

 

More Articles ...

circutor32x32

Contact

CIRCUTOR, SA
Vial Sant Jordi s/n, 08232
Viladecavalls (Barcelona) Spain
Tel: (+34) 93 745 29 00
Fax (+34) 93 745 29 14

Technical Support

(+34) 93 745 29 19

SAT

© 2015 circutor.com. All rights reserved.